JUTA

JUNIFOL HDPE CE

JUNIFOL – HDPE (Smooth) is a high-density polyethylene membrane, for use in accordance with
harmonised standards:

  • BS EN 13361: Characteristics required for use in the construction of reservoirs and dams.
  • BS EN 13362: Characteristics required for use in the construction of canals.
  • BS EN 13492: Characteristics required for use in the construction of liquid waste disposal sites, transfer stations, or secondary containment.
  • BS EN 13493: Characteristics required for use in the construction of solid waste storage and disposal sites.
  • BS EN 15382: Characteristics required for use in the construction of transportation infrastructure.
Read More

Product Benefits

  • High-Performance Polyethylene Geomembrane
  • Complies with the latest Codes of Practice
  • Flat Die Extrusion Technology
  • Good Welding Capabilities
  • Enhanced Flexibility and Elongation
Product Description

JUNIFOL LLDPE can be used on a wide range of applications where there is a need to contain and manage water.

This product is associated with the following NBS Create Clause:

  • 45-65-50/325 Plastic Sheets

 

This product is associated with the following NBS Clauses:

  • D20 Excavating and Filling
  • 550 GEOTEXTILE SHEET
  • J40 Flexible Sheet Waterproofing/ Damp Proofing
  • 140 LOOSE LAID POLYETHYLENE GAS RETARDANT/ DAMP PROOFING
  • 145 LOOSE LAID WELDABLE POLYETHYLENE GAS RETARDANT DAMP PROOFING
  • J44 Sheet Linings for pools/lakes/waterways
  • 110 GEOMEMBRANE LINING
  • 115 GEOMEMBRANE LINING

 

CharacteristicTest MethodJUNIFOL HDPE CE Thickness
1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
MaterialDSC AnalysisHigh Density Polyethylene (HDPE)
SurfaceSmooth/Smooth [G/G]
WidthEN 1848-25.1 m or 8.0 m
CharacteristicTest MethodJUNIFOL HDPE CE Thickness
ThicknessEN 1849-21.0 (±10%) mm1.5 (±10%) mm2.0 (±10%) mm2.5 (±10%) mm3.0 (±10%) mm
DensityEN ISO 1183≥0.942 g/cm3
Dimensional StabilityEN 1107-2±2 %
CharacteristicTest MethodJUNIFOL HDPE CE Thickness
1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
Permeability to LiquidsEN 14150< 1.0 x 10-6 m3/(m2.d)
Gas PermeabilityASTM D 1434< 6.03 x 10-3 mol/(m2.d)
CharacteristicTest MethodJUNIFOL HDPE CE Thickness
1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
Tensile Strength (MD/CMD)EN ISO 527-1,3 Specimen type 5 Velocity 100mm/min32/32 (>28/28) N/mm2
Elongation (MD/CMD)EN ISO 527-1,3 Specimen type 5 Velocity 100mm/min800/800 (>700/700) %
Strength at yield (MD/CMD)EN ISO 527-1,3 Specimen type 5 Velocity 100mm/min18/18 (>12/12) N/mm2
Elongation at yield (MD/CMD)EN ISO 527-1,3 Specimen type 5 Velocity 100mm/min12/12 (>10/10) %
Puncture ResistanceEN ISO 122363.2 (2.7) kN4.3 (3.7) kN5.0 (4.5) kN6.0 (5.5) kN6.0 (5.5) kN
Tear Strength (graves)ISO 34-1130 (120) 112 (150) N/mm(N)130 (120) 168 (155) N/mm(N)130 (120) 224 (210) N/mm(N)130 (120) 279 (265) N/mm(N)130 (120) 336 (315) N/mm(N)
Frictional Characteristics (Direct Shear)EN ISO 12957-122 (G) Vs Standard Sand degree
CharacteristicTest MethodJUNIFOL HDPE CE Thickness
1.0 mm1.5 mm2.0 mm2.5 mm3.0 mm
Foldability at Low temperatureEN 495-5-30oC
Linear thermal expansion coefficientASTM D 6962.0 x 10-4 mm/(mm.K)
  • Handling – Roll Weights can be in excess of 200kg and hence appropriate care and equipment is required for unloading and handling
  • Installation – JUNIFOL HDPE should be installed in accordance with the product installation guide.
  • Storage – Rolls of JUNIFOL HDPE should be stored on stable/level ground and stacked not more than five rolls high, with no other material stacked on top. The rolls can be stored outdoors when packaged but should be protected from exposure to UV.
  • Jointing and Sealing –  JUNIFOL HDPE should be jointed and sealed in accordance with the product installation guidelines.
Site Investigation
Site Investigation
Site Investigation Reports Monitoring Results. We review these reports and advise routes for compliance.
System Design
System Design
Full Ground Gas Protection System Design available.
Specification
Specification
Wide library of standard details with site specific details on request.
Installation
Installation
All our installers are certified NVQ Level 2 qualified installation contractors.
Validation
Validation
We ensure your project complies with the relevant building regulations.

Ground Gas Standards 

There are many different standards and guidance documents that detail how to understand the risk of ground contamination, and design solutions to mitigate these risks. The different documents relate to different ground contamination. Below are some of the key documents to be aware of and refer to:

BS 8485:2015+A1:2019 – Codes of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings.

  • Ground gases typically found near landfill sites, but can occur from other sources
  • Encourages the use of qualified installers
  • Validation to Ciria C735 is a requirement
  • Additional influences on the system should be considered, such as the hydrostatic conditions, and the likelihood of the source contaminant being in direct contact with the protective measures proposed
JUNIFOL HDPE CE

BRE 211:2015 – Guidance on protective measures for new buildings. (RADON)

  • Naturally occurring ground gas. Larger concentrations in the South-West of UK
  • Minimum recommendation is a membrane of 300 micrometre (1200 gauge) polyethylene sheet or equivalent
  • It must be installed with considerable care and protected once installed
  • Taped laps are required
JUNIFOL HDPE CE

CIRIA C748:2014 – Guidance on the use of plastic membranes as VOC vapour barriers

CIRIA C682:2009 – VOC Handbook

  • Risk-based approach
  • No quantifiable limits on material performance
  • Testing to ISO 15105-2 and EN 14414/EN 14415\
  • 9 main VOC types are tested for
  • Welded laps are required as most tapes are made from bitumen/butyl and are affected by VOCs
JUNIFOL HDPE CE

CIRIA C735:2014 – Good practice on testing and verification of protection systems to buildings from hazardous gases

  • Good practice on testing and verification of protection systems to buildings from hazardous gases
  • Check design and detailing is in accordance with site requirements
  • Checks the competency of the installer (NVQ LEVEL 2 minimum)
  • Test integrity of the membrane/barrier system
  • Visual inspection
  • Written report on inspection/testing and sign-off

BS8102:2009 – Code of practice for protection of below ground structures against water from the ground

JUNIFOL HDPE CE

JUTA Solutions & Applications

Our gas protection membranes suit a variety of applications and situations, with our TITAN® range offering not only gas protection but also having superior waterproofing and invasive weed control qualities.

BRE 211 NHBC (Amber 1) BS8485:2015 + A1 2019 / NHBC (Amber 2) C748 C748 BS8102:2009 RPS178 C753 BBA Agreement Certificate
Radon Bulk Ground Gasses Cardbon Dioxide and Methane VOC Vapour Permeation Hydrocarbons Immersions TYPE-A Bonded Waterproofing Invasive Weed Control SuDs Impermeable Membrane
GP®1
GP®2
GP®4
GP®5
GP®H
GP®L
GP® TITANFLEX
GP® TITANBOND
GP® TITANTANK
GP® LIQUID BARRIER
GP®H 0.6mm

Get In Touch With The Experts

If you feel first class service, premium products direct from source, and bespoke solutions are right for you then don't hesitate to contact our team today on 01772 754177 or email us at info@juta.co.uk

Contact Us